Adv Healthc Mater
- LIU X, Li K, Zhang B, Xu Z, et al
A Self-Powered, Cold-Responsive Pyroelectric Biointerface Restores Implant
Osseoperception and Osseointegration.
Adv Healthc Mater. 2026;15:e71305.
BMC Complement Med Ther
- KAURANI P, Chauhan R, Jayasinghe RM, Rasnayaka S, et al
Plant-based treatment modalities for peri-implant diseases: a scoping review.
BMC Complement Med Ther. 2026;26:96.
BMC Med Educ
- NALAMPANG S, Yanchinda J, Prapayasatok S, Charuakkra A, et al
Digital and immersive approaches to anatomy education: a pilot comparative study
of CI, VR, and hybrid learning in implant planning.
BMC Med Educ. 2026;26:681.
BMC Med Imaging
- BEDER M, Korkmaz MZ, Naralan ME, Keskin M, et al
Investigation of the effect of obesity on trabecular and cortical bone structure
in the peri-implant region using fractal analysis and radiomorphometric indices.
BMC Med Imaging. 2026;26:188.
BMC Oral Health
- ELNAGGAR HMMA, El-Gohary N, Yaseen AAM, Tawfik MA, et al
Extended platelet rich fibrin versus allograft as a space filling material in
immediate dental implant placement.
BMC Oral Health. 2026;26:1130.
- HELAL MH, Elguindy HM, Ghoraba SF, Shoukheba MY, et al
Fascia lata allograft versus subepithelial connective tissue graft for
peri-implant mucosal augmentation at implant placement: a randomized pilot
clinical trial.
BMC Oral Health. 2026;26:1123.
- LUNKAD H, Jethlia A, Sayed ME, Alshahrani AA, et al
Robotic technologies in prosthodontics and implantology: a scoping review of
current applications and future directions.
BMC Oral Health. 2026;26:1154.
- ZHU N, Liu Q, Chang Y, Zhang Y, et al
Comparison of the accuracy and efficiency of robot-assisted implant placement
using trephine versus conventional serial drilling: an in vitro study.
BMC Oral Health. 2026;26:1166.
- OZTURK E, von Krockow NG, Curcio R
Stress distribution of an anteriorly placed single implant in different clinical
scenarios: a 3D finite element analysis.
BMC Oral Health. 2026;26:1177.
- YAN M, Nie R, Ma Z, Song L, et al
Finite element analysis of stress distribution after folded and single-layer
fibular reconstruction with implant restoration for brown class ? mandibular
defects.
BMC Oral Health. 2026;26:1167.
- DOI K, Wakamatsu K, Oki Y, Oue H, et al
Correlation between drilling torque and cone-beam CT gray values: an exploratory
clinical study on bone density assessment using a measurement drill.
BMC Oral Health. 2026;26:1102.
- CI?FTCI? S, Kocamemi?k S, Aktas KA, Kosen BM, et al
Salivary contamination during implant placement: effects on titanium surface
properties and early osseointegration- a systematic review.
BMC Oral Health. 2026;26:1015.
- WANG Y, Chen S, Zhou Y
Implant-supported fixed prosthodontic treatment for ectodermal dysplasia: a case
report.
BMC Oral Health. 2026;26:1000.
- SAI?P S, Yesi?l Z
Effect of implant number, attachment type, and framework material on stress
distribution in mandibular overdentures: a finite element analysis.
BMC Oral Health. 2026;26:1035.
- KIM M, Kim KS, Lee SY
Long-term clinical outcomes in short (6 mm) versus standard (8.5 mm) implants: a
retrospective cohort study.
BMC Oral Health. 2026;26:924.
- ELSHOLKAMY M, Makawi DM, ElKhateeb SM, Soliman T, et al
Clinical, radiographic and histomorphometric assessment of the effects of
melatonin gel mixed with a xenograft in augmentation of the maxillary sinus: a
randomized controlled clinical trial.
BMC Oral Health. 2026;26:732.
- TIMARCIOGLU G, Kargu EC, Cerci Akcay H, Timarcioglu B, et al
Evaluating the reliability and educational quality of YouTube and TikTok videos
on custom subperiosteal implants: a cross-sectional methodological analysis.
BMC Oral Health. 2026;26:971.
- OZVERI KOYUNCU B, Gokce FM, Ozden Yuce M, Turk AG, et al
Effect of the number and localization of implants placed in the atrophic mandible
on the fragility of the symphysis region.
BMC Oral Health. 2026;26:875.
- LI P, Sun H, Wang X, Li X, et al
Micro/nano-structured titanium surfaces promote endothelial responses and
angiogenic activity under zoledronic acid exposure.
BMC Oral Health. 2026;26:823.
- ABLA MMA, Shaaban AM, Younis PA
Comparing two types of platelet-rich fibrin membranes in the management of
dehiscence defects with simultaneous implant placement in the posterior mandible:
a randomized controlled trial.
BMC Oral Health. 2026;26:591.
- WU Y, Wang H, Lin X, Zhou H, et al
Effect of immediate provisionalization using natural crowns with fiber splints on
gingival contour and esthetic outcomes after immediate implant placement: a
randomized clinical trial.
BMC Oral Health. 2026;26:777.
- ZADIKIAN CC, Clerc MM, Zadikian JL, Kerner S, et al
Impact of an open healing approach on peri-implant mucosa following immediate
implant placement with transmucosal provisionalization: a systematic review and
meta-analysis.
BMC Oral Health. 2026;26:759.
- ADNAN N, Ahmed SMF, Nooruddin A, Sadiq A, et al
A web-based deep learning cascade for automated detection and quantification of
marginal bone loss.
BMC Oral Health. 2026;26:590.
- GONULDAS F, Alan A, Buyuksungur A, Akat B, et al
Predicting fracture risk in Y-TZP zirconia implants using radiomics-based
artificial intelligence.
BMC Oral Health. 2026;26:640.
- SINGHANIA A, Borle AB, Godbole S, Nimonkar S, et al
Correlation between insertion torque value and bone density in D3 and D4 bone
following photobiomodulation: a randomised interventional study.
BMC Oral Health. 2026;26:561.
- LIU F, Yuan F, Li T, Ying W, et al
Clinical evaluation of a modified maxillary sinus floor elevation technique with
immediate implant placement: a retrospective study.
BMC Oral Health. 2026;26:479.
- ANDRADE NR, Gonzalez MIA, Mosaddad SA, Revilla-Leon M, et al
Accuracy of complete-arch digital implant impressions using conventional
scanbodies, ScanTransfers, and splinted ScanTransfers: an in vitro study.
BMC Oral Health. 2026;26:532.
- PARLAK HM, Ozkul C, Akman AC, Guncu GN, et al
Submucosal microbiota profile in peri-implant health, peri-implant mucositis, and
different severity levels of peri-implantitis.
BMC Oral Health. 2026;26:530.
- ZHANG H, Wei Y, Hu W, Xu T, et al
Virtual and clinical implant placement after ridge preservation in periodontally
compromised molars: retrospective study.
BMC Oral Health. 2026;26:526.
- JIANG W, Li J, Xie C, Yan M, et al
Extraction and implant restoration of an inverted impacted anterior tooth with
severe crown-root dilaceration: a 4-year follow-up case report.
BMC Oral Health. 2026;26:519.
- EID HS, Radwan M, Blunt L, Bills P, et al
Passive fit of milled and additively manufactured complete arch implant-supported
titanium frameworks: a micro-CT analysis.
BMC Oral Health. 2026;26:390.
- ZHENG S, Xia J, Guo B, Chen J, et al
Can a novice dentist, using a dynamic navigation system, achieve the accuracy of
experts using freehand implant placement? a retrospective study.
BMC Oral Health. 2026;26:467.
- DA SILVA RESENDE C, Nascimento LRM, Francescato O, de Lima RR, et al
Comparative in vitro evaluation of the mechanical behavior of implant-abutment
connections for zirconia and titanium implants.
BMC Oral Health. 2026;26:456.
- INAL S, Ugur M
A comparative in vitro study of the accuracy and precision of different intraoral
scanners for implant-supported hybrid prostheses impressions.
BMC Oral Health. 2026;26:341.
- LI F, Wu M, Zhang X, Bi M, et al
The effect of varying the position of implant screw access opening on the stress
distribution of sealing composite resin: a 3D-FEA study.
BMC Oral Health. 2026;26:271.
- MALEKAHMADI B, Kheirmand-Parizi M, Mikolai C, Winkel A, et al
Establishment of a three-dimensional in vitro peri-implant bone-mucosa composite
model.
BMC Oral Health. 2026;26:91.
- LEE SJ, Kwon JH, Choi YS, Yun PY, et al
Biofluorescence imaging-guided implantoplasty for the management of
peri-implantitis: a retrospective case series.
BMC Oral Health. 2026;26:145.
- MURAKAMI T, Asaka K, Ikumi R, Miyashita T, et al
Implant?position reproducibility of wired and wireless intraoral scanners and the
effects of Wi?Fi distance and upload speed: an in vitro study.
BMC Oral Health. 2026;26:257.
- AL-AWADHI ZA, Zhu S, Ren J, Geng N, et al
One-year clinical and radiographic outcomes of immediate versus delayed placement
of wide-diameter implants in the mandibular molar region.
BMC Oral Health. 2026;26:137.
- TAMBUN DV, Tanandika J, Carlita C, Ayub FA, et al
The role of medium-rough implant surface topography on macrophages polarization
in age-independent manner.
BMC Oral Health. 2026;26:234.
- CINAR G, Demir N, Guven ME
Evaluation of model accuracy and implant analog position in stone and additively
manufactured models with different resin viscosities.
BMC Oral Health. 2025;25:1942.
- BEHFARNIA P, Meshkinnejad R, Ahmadishadmehri M, Afshari Z, et al
Anatomic considerations for immediate implant placement in the mandibular
posterior region -A systematic review and meta-analysis.
BMC Oral Health. 2025;25:1924.
- ABDELMAGED HA, Moustafa AA, Khalil AA
Modified vascularized interpositional periosteal connective tissue graft versus
xenogeneic collagen matrix for soft tissue augmentation around implant in
esthetic zone (A comparative Study).
BMC Oral Health. 2025;25:1932.
- LIU Y, Yang J, Guo Y, Liu Q, et al
Photocatalytic cleaning effect of TiO(2) nanowires increase the osteoconductivity
of the titanium surface.
BMC Oral Health. 2025;25:1886.
BMC Res Notes
- ERDENOL E, Sancar E, Celik O, Erkut S, et al
Prosthetic complications of implant-supported overdentures: a retrospective study
on the influence of attachment type and implant number.
BMC Res Notes. 2026;19:76.
Braz Dent J
- MECCA S JR, Mecca MA, Jarry CR, Napimoga MH, et al
Accuracy of implants placed with CAD-CAM surgical templates using metal or peek
sleeve: an in vitro analysis.
Braz Dent J. 2026;37:e256696.
Case Rep Dent
- GEDEONOVA D, Fatyga MJ, Hrdinka M, Stembirek J, et al
Conservative Retention of Pre-Existing Dental Implants Contralateral to Adjuvant
Radiotherapy for Maxillary Oral Squamous Cell Carcinoma: A 4-Year Follow-Up Case
Report.
Case Rep Dent. 2026;2026:4881094.
Clin Exp Dent Res
- SOLTANI P, Manouchehri MH, Rostamian S, Devlin H, et al
Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior
Alveolar Canal Perforations by Zirconia Implants in CBCT Images.
Clin Exp Dent Res. 2026;12:e70397.
- SAMPAIO-OLIVEIRA M, Fagundes FB, Marinho-Vieira LE, Spin-Neto R, et al
Do Artifacts From Dental Implants Impair the Diagnosis of Simulated Internal Root
Resorption in Cone-Beam CT?
Clin Exp Dent Res. 2026;12:e70373.
Clin Implant Dent Relat Res
- CHEN N, Deng N, He T, Zhang H, et al
Transcrestal Sinus Floor Elevation Using Dental Implant Robot and
Osseodensification Drills: A Preliminary Case Series.
Clin Implant Dent Relat Res. 2026;28:e70167.
- WANG Y, Zhang J, Wu R, Fu G, et al
Peri-Implant Tissue Stability Following Guided Bone Regeneration With Bioceramic:
A Multicenter One-Year Cohort Study.
Clin Implant Dent Relat Res. 2026;28:e70170.
Clin Oral Investig
- KUPKA JR, Renouard F, Sagheb K, Al-Nawas B, et al
Safer and faster: evaluation of a dental implant checklist.
Clin Oral Investig. 2026;30:304.
- DENG C, Rao C, Song W, Xing Y, et al
Effectiveness and influencing factors of strip-cushioning transcrestal sinus
floor elevation: a clinical retrospective study.
Clin Oral Investig. 2026;30:197.
- KASSEM BA, Osman SM, El-Mahallawy Y
Effect of diode laser biostimulation on implant stability, post-surgical
inflammation, and bone healing in immediate implant in the maxillary premolars. A
randomized double-blind trial.
Clin Oral Investig. 2026;30:175.
- LUTERBACH DP, Souza LFB, Eyuboglu TF, Ozcan M, et al
Hydrophilicity, wettability, and elemental analysis of zirconia implant ceramic
after surface conditioning methods as a function of storage time.
Clin Oral Investig. 2026;30:167.
- AYYILDIZ BG, Eken S, Terzioglu B
The effect of the injectable platelet-rich fibrin on peri-implant soft tissue
phenotype: a preliminary, prospective, 12-month follow-up clinical study.
Clin Oral Investig. 2026;30:159.
- ULASTAN B, Dag A, Ortac H
Shallow vestibular depth as a risk indicator for peri-implantitis: a
retrospective analysis of 336 implants.
Clin Oral Investig. 2026;30:132.
- SALYBI SRB, Ramos FIR, Possebon APDR, Chagas-Junior OL, et al
Immediate versus conventional loading in users of mandibular overdentures
retained by narrow-diameter implants: results from a 5-year randomized clinical
trial.
Clin Oral Investig. 2026;30:53.
Cureus
- CROSSANOFF AF, Balanoff WL
Improvements in Social Quality of Life for Recovering Addicts Receiving Dental
Implant Rehabilitation.
Cureus. 2026;18:e110049.
Evid Based Dent
- JANDU J, Maharajan V, Pereira Carvalho R
Does using concave abutments improve 24-month outcomes of single posterior
implants?
Evid Based Dent. 2026;27:34-35.
Front Public Health
- USTUNDAG I, Bolukbasi S, Sancar B, Akmese R, et al
Oral health and public speaking attitudes after dental implant treatment in
septuagenarians: a comparative study.
Front Public Health. 2026;14:1840468.
Head Face Med
- ZHU W, Yang S, Lin P, Zhu Z, et al
CBCT-based virtual surgical planning for predicting risk factors and preventive
strategies of buccal plate perforation in maxillary premolar implant placement.
Head Face Med. 2026;22:46.
Int J Dent Hyg
- JAMJOOM A
Awareness and Usage of Water Irrigation Devices Among Implant Patients: A
Cross-Sectional Study.
Int J Dent Hyg. 2026;24:481-491.
- LIMA BD, Juarez HAB, Islabao FB, Pola NM, et al
Who Gets to Be Read? Factors Affecting Full-Text Access Rates in Periodontology
and Implantology Research.
Int J Dent Hyg. 2026;24:362-368.
Int J Implant Dent
- SATO Y, Uto Y, Odatsu T, Arai M, et al
Effect of three-segment scanning on the accuracy of intraoral scans in full-arch
implant-supported rehabilitation: an in vitro study.
Int J Implant Dent. 2026;12:32.
Int J Oral Maxillofac Surg
- RATTAN S, Sabu AM, Varghese KG, Kurian N, et al
Accuracy of implant placement using surgical guides in edentulous patients: a
systematic review and meta-analysis.
Int J Oral Maxillofac Surg. 2026;55:969-976.
J Dent
- LIU X, Cai Z, Chen C, Zhang J, et al
Evaluation of intravenous sedation in dental implant surgeries: a prospective
cohort study.
J Dent. 2026 Jun 27:106865. doi: 10.1016/j.jdent.2026.106865.
J Indian Prosthodont Soc
- SHINDE KS, Raghavendra Prasad S, Chethana K
Impact of repeated usage of two different scan bodies on the accuracy of implant
position transfer: An in vitro study.
J Indian Prosthodont Soc. 2026;26:283-288.
- AGRAWAL KK, Goel P, Bakrolwala H
Association of menopausal status and genetic polymorphisms with early crestal
bone loss around dental implants: A prospective observational study.
J Indian Prosthodont Soc. 2026;26:252-259.
- RAGHER M, Shetty SK, Shetty R, Sarfaraz MH, et al
Impact of biomaterials on intra-sinus bone changes around dental implants
following indirect sinus augmentation: A randomized clinical trial.
J Indian Prosthodont Soc. 2026;26:215-222.
J Oral Maxillofac Surg
- COSOLA S, Vatteroni E, Asadi M, Covani U, et al
Clinical Outcomes, Survival, and Complications of Customized Computer-Aided
Design and Manufacturing 3-Dimensional-Printed Titanium Subperiosteal Implants.
J Oral Maxillofac Surg. 2026;84:1084-1094.
J Prosthet Dent
- REVILLA-LEON M, Lawand G, Oh KC, Barmak AB, et al
Impact of number of maxillary fixation landmarks on the registration accuracy of
an implant scanning workflow.
J Prosthet Dent. 2026;136:229-238.
- ALVES TG, Bonadiman EA, Ruiz DC, Pereira TCR, et al
Influence of vertical X-ray beam angulation and receptor-holders on the
radiographic detection of implant abutment-prosthesis misfit.
J Prosthet Dent. 2026;136:282-287.
- REVILLA-LEON M, Drone M
Implant scanning workflow combining extraoral photogrammetry and the reverse
scanning method for fabricating implant-supported prostheses.
J Prosthet Dent. 2026;136:e22-e27.
- LI J, Yu J, Joda T, Mohamed FF, et al
Complete arch implant surgical guide for accurate implant scanning without
photogrammetry device: A workflow based on the calibrated intraoral scan protocol
(CISP).
J Prosthet Dent. 2026;136:17-21.
- WU J, Lin B, Yang S, Xu S, et al
Robot-assisted immediate implant placement with the socket shield technique in
the esthetic zone: A prospective 10-patient series.
J Prosthet Dent. 2026;136:117-126.
- KHER U, Nimbalkar S, Patil PG
Molar socket shield technique with immediate implant placement maintains stable
tissue architecture at 5- to 7-year follow-up: A clinical series.
J Prosthet Dent. 2026;136:111-116.
- ALTEMIMI A, Alzoubi F, Nogueira LP, Yilmaz B, et al
Screw preload analysis of direct-to-abutment connections in complete arch
zirconia frameworks before and after thermomechanical aging.
J Prosthet Dent. 2026;136:e290-e298.
- DAWOOD A, Darwood A
In situ repair of a fractured zygomatic implant.
J Prosthet Dent. 2026;136:8-12.
- GALVAO CS, Moreira FSR, Medeiros AKB, Bezerra PTM, et al
Complete arch digital implant scans in the edentulous maxilla: Trueness and time
efficiency based on scan body height, splinting, location, and scanner system.
J Prosthet Dent. 2026;136:e280-e289.
- TOMAR S, Agnihotri N, Vhanmane G
Prosthetic complications of implant-supported complete arch prostheses: An
umbrella review of systematic reviews.
J Prosthet Dent. 2026;136:52-59.
- ZHANG J, Chen G, Chen J, Luo Y, et al
Bibliometric analysis of implant abutment research from 2005 to 2024.
J Prosthet Dent. 2026;136:e185-e197.
- REVILLA-LEON M, Guinot-Barona C, Barmak AB, Kois JC, et al
Noncalibrated implant scan body system oriented toward the center of the arch:
Accuracy of complete arch implant scans recorded using five intraoral scanners.
J Prosthet Dent. 2026;136:e271-e279.
- REVILLA-LEON M, Barmak AB, Prasad S
Accuracy of complete arch implant scans using nonsplinting techniques: A
systematic review and meta-analysis. Report of the Committee on Research in Fixed
Prosthodontics of the American Academy of Fixed Prosthodon.
J Prosthet Dent. 2026;136:e102-e138.
- MATOS ACM, Vieira FL, Marrara JR, Tirapelli C, et al
Are monolithic zirconia complete arch implant-supported prostheses reliable? A
systematic review and meta-analysis.
J Prosthet Dent. 2026;136:40-51.
- ARAFA S, Abdelkader SH, Elsheemy A, Abdelraheem I, et al
Trueness of implant orientation transfer produced by intraoral scanning of
maxillary complete arch implant-supported restoration using different scan body
designs: An in vitro study.
J Prosthet Dent. 2026;136:e263-e270.
- ZHU N, Zhang Y
Computer-assisted autogenous shell technique and simultaneous implantation for
reconstruction of an atrophic alveolar ridge in the esthetic zone.
J Prosthet Dent. 2026;136:e28-e32.
- VARGHESE KG, Kurian N, Sudharson NA, Thomas PM, et al
A 3-dimensionally printed stackable device for verifying a complete arch implant
digital scan and recording the maxillomandibular relationship.
J Prosthet Dent. 2026;136:e44-e47.
- REVILLA-LEON M, Drone M
Maxillary implant workflow guided by anatomic structures as the predominant
reference landmark for noncalibrated, extraoral, and intraoral photogrammetry
implant scanning techniques.
J Prosthet Dent. 2026;136:22-29.
- PRASAD S, Barmak AB, Revilla-Leon M
A systematic review and meta-analysis of the accuracy of complete arch implant
scanning techniques performed extraorally: Reverse impression and extraoral
photogrammetry methods. Report of the Committee on Research in Fixed
Prosthodontics of the Ameri
J Prosthet Dent. 2026;136:e79-e101.
- REVILLA-LEON M, Guinot-Barona C, Barmak AB, Drone M, et al
Comparative accuracy study of three extraoral photogrammetry methods, one
intraoral photogrammetry system, and a noncalibrated implant scan body technique.
J Prosthet Dent. 2026;136:267-274.
- TENG YT, Hu CY, Lee WC, Yang TC, et al
Effects of repeated milling with a 1 mm small-diameter cutting tool on tool
dimensions and on the surface characteristics and marginal adaptation of zirconia
implant-supported restorations.
J Prosthet Dent. 2026;136:e335-e343.
- CORTASSE B, Tran ML, Mourlaas J, Cofar F, et al
Immediate implant placement in the esthetic zone with buccal wall defect using
the immediate dentoalveolar restoration (IDR) protocol: A clinical report.
J Prosthet Dent. 2026;136:e10-e14.
- REVILLA-LEON M, Lawand G, Mosaddad SA, Barmak AB, et al
Optimizing implant workflows: The role of fixation screws and tripod
configurations in enhancing mandibular registration accuracy.
J Prosthet Dent. 2026;136:275-281.
- E R, A JF, M SS, S P, et al
Damaged implant abutment screw retrieval using a surgical glove: A dental
technique.
J Prosthet Dent. 2026;136:e48-e50.
- KILIC L, Kumbuloglu TO, Comlekoglu MD, Gokce B, et al
Removal resistance of locking taper implant-abutment connections at different
strike numbers: An in vitro study.
J Prosthet Dent. 2026;136:e252-e262.
- REZAEI A, Fotovat F, Heidari A, Khayami Z, et al
Accuracy comparison of 3D printed tooth-supported implant surgical guides: A
prospective observational clinical study.
J Prosthet Dent. 2026;136:127-135.
J Proteome Res
- SOUZA LPSS, Dias DR, Cesar GPS, Bianco DA, et al
MS-Based Crevicular Fluid Proteomics for the Study of Periodontal and
Peri-Implant Conditions: A Systematic Review.
J Proteome Res. 2026;25:3217-3233.
Med Oral Patol Oral Cir Bucal
- AGOSTINI M, Gomez-Adrian MD, Barbera-Millan J
Primary stability of dental implants placed in low-density polyurethane blocks:
Undersized osteotomy versus osseodensification, an in vitro comparative study.
Med Oral Patol Oral Cir Bucal. 2026 Jun 29:28075. doi: 10.4317/medoral.28075.
Odontology
- LIU Y, Qu J, Zheng J
Clinical efficacy of free gingival graft versus collagen matrix for peri-implant
soft tissue augmentation: a systematic review and meta-analysis.
Odontology. 2026;114:1161-1177.
- ABDURAKHMON K, Wu J, Li S, Wei C, et al
Biomechanical evaluation of implant materials and connection designs: a
structured narrative review of titanium and zirconia.
Odontology. 2026;114:988-1004.
Oral Maxillofac Surg
- MARCONCINI S, Giammarinaro E, Baldini N, Canullo L, et al
Clinical outcomes of post-extractive tissue-level implants with transmucosal
zirconia collar: a prospective cohort study.
Oral Maxillofac Surg. 2026;30:63.
- TAO X, Jiang H, Sun Z, Xu C, et al
A Dynamic Navigation-Assisted Transcrestal Sinus Floor Elevation in Severely
Atrophic Maxillae: A Descriptive Case Series.
Oral Maxillofac Surg. 2026;30:56.
- PRADO WM, Asbi T, Martins R, Iezzi G, et al
Impact of additive manufacturing process of titanium implants on peri-implant
human bone.
Oral Maxillofac Surg. 2026;30:48.
PLoS One
- KELES M, Yuksel IB, Sen DO, Ogutcen O, et al
Evaluation of early trabecular changes around implants using fractal analysis and
panoramic indices.
PLoS One. 2026;21:e0352984.
Sci Rep
- ETIK E, Keskin Yalcin B
Biomechanical effect of implant thickness and screw diameter on CFR-PEEK
subperiosteal implants: a three-dimensional finite element analysis.
Sci Rep. 2026;16:19042.
- ASKIN EKINCI S, Fettahzade S, Gocmen G, Bayram F, et al
Virtual bone-implant contact surface effect on implant stability in fresh
extraction and healed sites: a pilot randomised clinical trial.
Sci Rep. 2026;16:17096.
- KIM H, Oh S, Hong JS, Kang MS, et al
Exploratory randomized trial of Weissella cibaria CMU and oral microbiome changes
in peri implant mucositis.
Sci Rep. 2026;16:12166.
- LI X, Deng H, Gu K, Wang Q, et al
Immediate four implants supported short arch rehabilitation for severe maxillary
edentulism.
Sci Rep. 2026;16:5736.
Zhonghua Kou Qiang Yi Xue Za Zhi
- WANG MX, Chen QQ, Wang JC, Wu J, et al
[Clinical comparative analysis of accuracy between tilted and axial implant
placement in edentulous jaws assisted by an autonomous dental implant robot].
Zhonghua Kou Qiang Yi Xue Za Zhi. 2026;61:979-985.
Free Medical Abstracts
Privacy Policy
Sponsors
Share
© Amedeo 1997-2016